The future of prostate cancer imaging: What do physicians want? March 5, 2026 ASX: TLX | Nasdaq: TLX

Presenters

Rodney Hicks, MD*

Chief Medical Officer and Nuclear Medicine specialist, Melbourne Theranostics Innovation Centre

Paul Yonover, MD*

Chief Data Officer and Director of Clinical Navigation, UroPartners, Chicago

David N. Cade, MD

Telix Group Chief Medical Officer

Darren Patti, PharmD

Telix Group Chief Operating Officer

*Independent expert speakers are not employees of Telix. Views are speaker's own.

3



68Ga-PSMA-11: Extensive published data and real-world experience1-9

Overall ≥80% sensitivity and ≥90% specificity,

based on a review of 76 published articles in >5,000 patients9



High true positive rates of detection for regional and distant metastases including bone and soft tissue1-5,8,9



High diagnostic performance for micrometastatic disease as small as 2 mm and very low PSA values (0.02 ng/mL)4,8,9



High diagnostic performance in pelvic bed, lymph nodes, and bladder neck9-11



High reproducibility and inter-reader agreement3,6,7



PET, positron emission tomography; PSA, prostate-specific antigen.

1. Rauscher I, et al. J Nucl Med. 2020;61(1):51-57. 2. Kroenke M, et al. J Nucl Med. 2021;62(8):1082-1088. 3. Illuccix prescribing information. Telix Pharmaceuticals; 2023. 4. Burgard C, et al. Cancers (Basel). 2023;15(5):1376. 5. Hagens MJ, et al. J Nucl Med. 2022;63(10):1531-1536. 6. Giesel FL, et al. Eur J Nucl Med Mol Imaging. 2015;42(12):1794-1800. 7. van Leeuwen PJ, et al. BJU Int. 2017;119(2):209-215. 8. Alipour R, et al. Ther Adv Med Oncol. 2019;11:1758835919876828. 9. Purysko AS, et al. Appl Radiol. 2024; 53(2):22-35. 10. Pallavi UN, et al. Indian J Nucl Med. 2020;35(2):93-99. 11. Yilmaz B, et al. Prostate. 2019;79(9):1007-1017.

4



Recent data: Illuccix China Phase 3 study (December 2025)

High PPV, including at low PSA values and across differing metastatic locations

Primary endpoint met decisively in 140 pts

  • Overall patient-level PPV of 94.8% for the detection of tumors with TLX591-Px (95% CI: 85.9%, 98.2%), with the lower

    bound of the 95% CI (85.9%).

  • Significantly exceeded predefined threshold of 60%

    Region-level PPV

  • 100.0% in the prostate bed, extra-pelvic soft tissue, lymph nodes, and organ metastases (non-bone)

  • 94.7% in the pelvic region outside of the prostate bed, including lymph nodes

  • 87.0% in bone metastases

High PPV in all PSA strata

Baseline PSA (ng/mL)

PPV (95% CI)

≥ 5.0

100.0% (78.5%, 100.0%)

< 5.0 to 2.0

100.0% (67.6%, 100.0%)

< 2.0 to 1.0

90.9% (62.3%, 98.4%)

< 1.0 to 0.5

90.0% (59.6%, 98.2%)

< 0.5 to 0.2

93.3% (70.2%, 98.8%)

Meaningful impact on clinical decision-making More than two-thirds (67.2%) of patients experienced a change in their treatment plan following TLX591-Px PSMA-PET imaging compared with the initial plan at baseline

1. Telix ASX disclosure December 22, 2025. Illuccix China Phase 3 Registration Study Clinical Study Report, December 2025.

5



68Ga-PSMA-11 PET detection in patients with very low PSA

Too Small? Technology and Technique Are the Answers

32-minute SFOV

4-minute EFOV

1-minute EFOV

30-second EFOV



Same patient Same PSA Same tracer





2 weeks apart

Conventional 60-min uptake

Optimised >120-min post-diuretic uptake

Patient representative scan - individual results may vary.

6





Gallium-68: Structural market leadership

A proven, scalable platform built for sustained growth



  • Multiple global generator manufacturers (and growing)

  • Multiple established and reliable sources of parent germanium-68

  • Convenient, dependable, on-demand and on-site access

  • Higher activity generators entering the market = scheduling flexibility and production efficiencies

  • Commercially available solid and liquid target solutions available for cyclotron produced material

  • Yields >5 Ci per production with ARTMS QIS®

  • Robust and cost-efficient suppliers of parent zinc-68 for target production

7



Gozellix grows Telix share by increasing access and efficiency

362 additional cameras in range



164 cameras can increase scan volumes

*Within 10 miles of current limit



Newly in range

Efficiency for accounts = more volume at more accounts



Allows for two product

strategy

8



Contact:

Kyahn Williamson

SVP Investor Relations and Corporate Communications

kyahn.williamson@telixpharma.com



Attention: This is an excerpt of the original content. To continue reading it, access the original document here.

Attachments

  • Original document
  • Permalink

Disclaimer

Telix Pharmaceuticals Ltd. published this content on March 05, 2026, and is solely responsible for the information contained herein. Distributed via Public Technologies (PUBT), unedited and unaltered, on March 05, 2026 at 01:47 UTC.